Comparison of Image Quality Between Conventional and Low-Dose Nonenhanced Head CT Export

AJNR Am J Neuroradiol, Vol. 25, No. 4. (1 April 2004), pp. 533-538.

Citation Format

[Posts]

View FullText article


MEHTRadiology's tags for this article

brain ct head multidetector multislice

X Reviews [Write a review of this article]

X Find related articles from these CiteULike users

X Find related articles with these CiteULike tags

X Posting History

X Abstract

BACKGROUND AND PURPOSE: Increasing use of CT for evaluating neurologic disease may expose patients to considerable levels of ionizing radiation. We compared the image quality of low-mAs head CT scans with that of conventional nonenhanced scans. METHODS: Conventional head CT scans were obtained in 20 patients (all >65 years with history of non-CNS malignancy) by using a multidetector technique: 170 mA and 1-second scanning time (ie, 170 mAs), 140 kVp, table speed of 7.5 mm per rotation, pitch of 0.75, section thickness of 5 mm, and field of view of 25 mm. A limited volume helical data acquisition covering four 5-mm-thick images was obtained by using 90 mAs but otherwise the same parameters. Three neuroradiologists visually rated the resulting images for quality in a blinded comparison. Representative 1- to 4-mm2 regions of interest were chosen in gray matter and white matter locations. Conspicuity and the contrast-to-noise ratio were analyzed. Statistical comparisons were done by using the Student t test. RESULTS: Mean gray matter conspicuity was not significantly different between the 170- and 90-mAs groups (0.39 +/- 0.19 vs 0.41 +/- 0.03, P = .32). Mean gray matter contrast-to-noise ratio was approximately 22% higher with 170 mAs than with 90 mAs (1.77 +/- 0.52 vs 1.39 +/- 0.38, P = .005). All 90-mAs images were rated as having slightly greater image noise than the 170-mAs scans but with sufficient perceived resolution. CONCLUSION: Although 90-mAs head CT images were moderately noisier than 170-mAs images, they were rated as having acceptable diagnostic quality.


X BibTeX record

X RIS record


Privacy Statement | Terms & Conditions
CiteULike organises scholarly (or academic) papers or literature and provides bibliographic (which means it makes bibliographies) for universities and higher education establishments. It helps undergraduates and postgraduates. People studying for PhDs or in postdoctoral (postdoc) positions. The service is similar in scope to EndNote or RefWorks or any other reference manager like BibTeX, but it is a social bookmarking service for scientists and humanities researchers.