Register | Log in | FAQ      [?] 

Tag electrodes [57 articles]

Recent papers classified by the tag electrodes.
  • Virtual electrodes in cardiac tissue: a common mechanism for anodal and cathodal stimulation.
    Biophys J, Vol. 69, No. 6. (December 1995), pp. 2195-2210.
    by JP Wikswo, SF Lin, RA Abbas
  • Virtual sources associated with linear and curved strands of cardiac cells.
    Am J Physiol Heart Circ Physiol, Vol. 279, No. 4. (October 2000)
    by L Tung, AG Kléber
  • Separation and concentration effect of f-MWCNTs on electrocatalytic responses of ascorbic acid, dopamine and uric acid at f-MWCNTs incorporated with poly (neutral red) composite films
    Electrochimica Acta, Vol. 52, No. 19. (25 May 2007), pp. 5985-5996.
    by Umasankar Yogeswaran, Shen-Ming Chen
  • Electroanalytical properties of cytochrome c by direct electrochemistry on multi-walled carbon nanotubes incorporated with DNA biocomposite film
    Talanta, Vol. 74, No. 5. (15 February 2008), pp. 1659-1669.
    by Jan-Wei Shie, Umasankar Yogeswaran, Shen-Ming Chen
  • Nanocomposite of functionalized multiwall carbon nanotubes with nafion, nano platinum, and nano gold biosensing film for simultaneous determination of ascorbic acid, epinephrine, and uric acid
    Analytical Biochemistry, Vol. 365, No. 1. (1 June 2007), pp. 122-131.
    by Umasankar Yogeswaran, Soundappan Thiagarajan, Shen-Ming Chen
  • Multi-walled carbon nanotubes with poly(methylene blue) composite film for the enhancement and separation of electroanalytical responses of catecholamine and ascorbic acid
    Sensors and Actuators B: Chemical, Vol. In Press, Corrected Proof
    by Umasankar Yogeswaran, Shen-Ming Chen
  • Electrocatalytic properties of electrodes which are functionalized with composite films of f-MWCNTs incorporated with poly(neutral red)
    J Electrochem Soc, Vol. 154, No. 11. (2007)
    by U Yogeswaran, SM Chen
  • On-electrode autonomous current generator for multi-frequency EIT
    Physiological Measurement, Vol. 29, No. 6. (2008), pp. S193-S201.
    by I Jivet, B Dragoi
    posted to current-source electrodes instrumentation by tuckmobile on 2008-06-19 05:00:14 as ****
  • Current injection electrodes for electrical impedance tomography
    Physiological Measurement, Vol. 25, No. 4. (2004), pp. 797-802.
    posted to electrodes instrumentation by tuckmobile on 2008-05-16 19:02:23 as **
  • Errors due to measuring voltage on current-carrying electrodes in electric current computed tomography
    Biomedical Engineering, IEEE Transactions on, Vol. 37, No. 1. (1990), pp. 60-65.
    by KS Cheng, SJ Simske, D Isaacson, JC Newell, DG Gisser
    posted to drive-patterns electrodes errors by tuckmobile on 2008-06-04 21:41:22 as *****
  • notes Driven-Right-Leg Circuit Design
    Biomedical Engineering, IEEE Transactions on, Vol. BME-30, No. 1. (1983), pp. 62-66.
    by Bruce B Winter, John G Webster
    posted to electrodes instrumentation by tuckmobile on 2008-05-27 21:22:28 as **
  • Minimizing Silver-Silver Chloride Electrode Impedance
    Biomedical Engineering, IEEE Transactions on, Vol. BME-23, No. 1. (1976), pp. 87-88.
    by Walter A Getzel, John G Webster
    posted to electrodes by tuckmobile on 2008-05-31 07:09:19 as **
  • Electrode models for electric current computed tomography
    Biomedical Engineering, IEEE Transactions on, Vol. 36, No. 9. (1989), pp. 918-924.
    by Kuo-Sheng Cheng, D Isaacson, JC Newell, DG Gisser
    posted to electrodes theory by tuckmobile on 2008-06-04 21:42:21 as **
  • L.A. Geddes: a biomedical engineering activist
    Engineering in Medicine and Biology Magazine, IEEE, Vol. 18, No. 2. (1999), pp. 6-7.
    by AYJ Szeto
    posted to biographical electrodes by tuckmobile on 2008-05-31 06:59:27 as **
  • Using compound electrodes in electrical impedance tomography
    Biomedical Engineering, IEEE Transactions on, Vol. 40, No. 1. (1993), pp. 29-34.
    by P Hua, EJ Woo, JG Webster, WJ Tompkins
    posted to electrodes by tuckmobile on 2008-05-27 21:19:44 as **
  • Patient Electrode Isolation Adapter
    Biomedical Engineering, IEEE Transactions on, Vol. BME-18, No. 6. (1971), pp. 428-430.
    by William P Holsinger, Kenneth M Kempner
    posted to dc-blocking electrodes instrumentation by tuckmobile on 2008-05-27 23:07:54 as **
  • A surface EMG electrode for the simultaneous observation of multiple facial muscles
    Journal of Neuroscience Methods, Vol. 123, No. 2. (15 March 2003), pp. 117-128.
    by BG Lapatki, DF Stegeman, IE Jonas
    posted to electrodes by tuckmobile on 2008-05-31 06:52:36 as ** along with 1 person ganeshrnaik
  • Single-walled carbon nanotubes deposited on surface electrodes to improve interface impedance
    Physiological Measurement, Vol. 29, No. 6. (2008), pp. S203-S212.
    posted to electrodes by tuckmobile on 2008-06-19 05:02:13 as ****
  • Harmonic analysis of low-frequency bioelectrode behavior
    Medical Imaging, IEEE Transactions on, Vol. 21, No. 6. (2002), pp. 604-612.
    posted to electrodes errors noise by tuckmobile on 2008-06-04 21:16:20 as **
  • Skin impedance from 1 Hz to 1 MHz
    Biomedical Engineering, IEEE Transactions on, Vol. 35, No. 8. (1988), pp. 649-651.
    posted to electrodes by tuckmobile on 2008-05-27 20:54:46 as **
  • A compensated radiolucent electrode array for combined EIT and mammography
    Physiological Measurement, Vol. 28, No. 7. (2007), pp. S291-S299.
    by Tzu-Jen Kao, GJ Saulnier, Hongjun Xia, Chandana Tamma, JC Newell, D Isaacson
    posted to eit_applications electrodes by tuckmobile on 2008-06-05 04:18:38 as **
  • Influence of electrode impedance changes on the common-mode rejection ratio in bioimpedance measurements
    Physiological Measurement, Vol. 20, No. 4. (1999), pp. N11-N19.
    by Galidia I Petrova
    posted to electrodes errors by tuckmobile on 2008-05-16 18:38:55 as **
  • The complete electrode model for EIT in a mammography geometry
    Physiological Measurement, Vol. 28, No. 7. (2007), pp. S57-S69.
    by Bong S Kim, Gregory Boverman, Jonathan C Newell, Gary J Saulnier, David Isaacson
  • Current Patterns and Electrode Types for Single-Source Electrical Impedance Tomography of the Thorax
    Annals of Biomedical Engineering, Vol. 26, No. 2. (1 March 1998), pp. 253-259.
    by Thomas F Schuessler, Jason H Bates
    posted to drive-patterns electrodes single-source by tuckmobile on 2008-05-16 18:20:25 as **
  • Inflatable belt for the application of electrode arrays
    Review of Scientific Instruments, Vol. 71, No. 2. (2000), pp. 530-535.
    by RJ Sadleir, RA Fox, VF Turner
    posted to belt electrodes by tuckmobile on 2008-05-16 18:46:55 as **
  • Electrical impedance endo-tomography: imaging tissue from inside
    Medical Imaging, IEEE Transactions on, Vol. 21, No. 6. (2002), pp. 560-565.
    posted to eit_applications electrodes by tuckmobile on 2008-06-04 21:10:13 as **
  • A reconstruction algorithm for electrical impedance tomography data collected on rectangular electrode arrays
    Biomedical Engineering, IEEE Transactions on, Vol. 46, No. 11. (1999), pp. 1379-1386.
    by JL Mueller, D Isaacson, JC Newell
    posted to 3deit algorithms eit_applications electrodes reconstruction by tuckmobile on 2008-06-04 21:31:40 as **
  • A micropower dry-electrode ECG preamplifier.
    IEEE Trans Biomed Eng, Vol. 47, No. 2. (February 2000), pp. 155-162.
    by MJ Burke, DT Gleeson
  • Rapid assessment of electrode characteristics for impedance imaging
    Biomedical Engineering, IEEE Transactions on, Vol. 37, No. 7. (1990), pp. 735-738.
    by JC Newell, D Isaacson, DG Gisser
    posted to electrodes by tuckmobile on 2008-06-04 21:40:26 as **
  • Patient-instrument connection errors in bioelectrical impedance measurement.
    Physiological measurement, Vol. 19, No. 2. (May 1998), pp. 285-296.
    posted to electrodes errors by tuckmobile on 2008-05-16 18:41:10 as **
  • Globus pallidus internus stimulation in primary generalized dystonia: a H215O PET study
    Brain, Vol. 127, No. 8. (1 August 2004), pp. 1899-1908.
    by Olivier Detante, Laurent Vercueil, Stephane Thobois, Emmanuel Broussolle, Nicolas Costes, Franck Lavenne, Stephan Chabardes, Didier Lebars, Marie Vidailhet, Alim-Louis Benabid, Pierre Pollak
    posted to electrodes stimulation water by Tominator on 2008-01-30 08:40:20 as read along with 1 person ntvandehey
  • Small animal positron emission tomography during vagus nerve stimulation in rats: A pilot study
    Epilepsy Research, Vol. 67, No. 3. (December 2005), pp. 133-141.
    by Stefanie Dedeurwaerdere, Bart Cornelissen, Koen Van Laere, Kristl Vonck, Eric Achten, Guido Slegers, Paul Boon
    posted to electrodes fdg rat stimulation by Tominator on 2008-01-29 10:21:11 as read
  • Deep Brain Stimulation to Reward Circuitry Alleviates Anhedonia in Refractory Major Depression
    Neuropsychopharmacology, Vol. aop, No. current.
    by Thomas E Schlaepfer, Michael X Cohen, Caroline Frick, Markus Kosel, Daniela Brodesser, Nikolai Axmacher, Alexius Y Joe, Martina Kreft, Doris Lenartz, Volker Sturm
  • Poly(4-amino-1-1'-azobenzene-3, 4'-disulfonic acid) coated electrode for selective detection of dopamine from its interferences
    Talanta, Vol. 74, No. 4. (15 January 2008), pp. 860-866.
    by Ashok S Kumar, Chun-Fang Tang, Shen-Ming Chen
    posted to electrodes modified polymer by sakumar80 on 2008-03-05 10:13:39 as *****
  • Nanostructured Zinc Oxide Particles in Chemically Modified Electrodes for Biosensor Applications
    Analytical Letters, Vol. 41, No. 2. (2008), pp. 141-158.
    by Ashok S Kumar, Shen-Ming Chen
    posted to electrodes modified oxide zinc by sakumar80 on 2008-03-05 10:22:09 as **
  • First human trials of a dry electrophysiology sensor using a carbon nanotube array interface
    (14 Jan 2007)
    posted to cnts dry eeg electrodes nanotubes by ruffini on 2007-12-12 10:20:55 as read
  • Long term in vitro monitoring of polyimide microprobe electrical properties
    Engineering in Medicine and Biology Society, 2003. Proceedings of the 25th Annual International Conference of the IEEE, Vol. 4 (2003), pp. 3340-3343 Vol.4.
    by SA Nikles, DS Pellinen, J Kitagawa, RM Bradley, DR Kipke, K Najafi
    posted to electrodes neural polyimide swelling by mrjpharris on 2006-03-22 20:07:19 as read
  • Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film.
    J Neural Eng, Vol. 3, No. 1. (March 2006), pp. 59-70.
    by KA Ludwig, JD Uram, J Yang, DC Martin, DR Kipke
  • A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex.
    J Neural Eng, Vol. 2, No. 4. (December 2005), pp. 103-113.
    by J Subbaroyan, DC Martin, DR Kipke
  • Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex.
    IEEE Trans Biomed Eng, Vol. 39, No. 6. (June 1992), pp. 635-643.
    by DJ Edell, VV Toi, VM McNeil, LD Clark
  • Implantable neural probe systems for cortical neuroprostheses
    Engineering in Medicine and Biology Society, 2004. EMBC 2004. Conference Proceedings. 26th Annual International Conference of the, Vol. 2 (2004), pp. 5344-5347 Vol.7.
    by DR Kipke
  • Response of brain tissue to chronically implanted neural electrodes.
    J Neurosci Methods, Vol. 148, No. 1. (15 October 2005), pp. 1-18.
    by VS Polikov, PA Tresco, WM Reichert
  • A flexible perforated microelectrode array for extended neural recordings.
    IEEE Trans Biomed Eng, Vol. 39, No. 1. (January 1992), pp. 37-42.
    by SA Boppart, BC Wheeler, CS Wallace
    posted to brain-slice electrodes microelectrode neural polyimide by mrjpharris on 2006-03-22 18:33:46 as read
  • Parylene flexible neural probes integrated with microfluidic channels.
    Lab Chip, Vol. 5, No. 5. (May 2005), pp. 519-523.
    posted to cortical electrodes implant microelectrode microfluidic neural peg by mrjpharris on 2006-03-22 18:27:37 as read
  • Massively parallel recording of unit and local field potentials with silicon-based electrodes.
    J Neurophysiol, Vol. 90, No. 2. (August 2003), pp. 1314-1323.
    by J Csicsvari, DA Henze, B Jamieson, KD Harris, A Sirota, P Barthó, KD Wise, G Buzsáki
  • Controlling cellular reactive responses around neural prosthetic devices using peripheral and local intervention strategies.
    IEEE Trans Neural Syst Rehabil Eng, Vol. 11, No. 2. (June 2003), pp. 186-188.
  • Dexamethasone treatment reduces astroglia responses to inserted neuroprosthetic devices in rat neocortex.
    Exp Neurol, Vol. 194, No. 2. (August 2005), pp. 289-300.
    by L Spataro, J Dilgen, S Retterer, AJ Spence, M Isaacson, JN Turner, W Shain
  • An economical multi-channel cortical electrode array for extended periods of recording during behavior.
    J Neurosci Methods, Vol. 142, No. 1. (15 March 2005), pp. 97-105.
    by RL Rennaker, AM Ruyle, SE Street, AM Sloan
    posted to auditory chronic cortex electrodes implant neural by mrjpharris on 2006-03-22 19:03:34 as read
  • Biocompatible benzocyclobutene (BCB)-based neural implants with micro-fluidic channel.
    Biosens Bioelectron, Vol. 20, No. 2. (15 September 2004), pp. 404-407.
    by K Lee, J He, R Clement, S Massia, B Kim
  • Implantable bioelectric interfaces for lost nerve functions.
    Prog Neurobiol, Vol. 55, No. 5. (August 1998), pp. 433-461.
  • Note: You may cite this page as: http://www.citeulike.org/tag/electrodes

    Result page: 1 2 Next RIS BibTeX
    CiteULike organises scholarly (or academic) papers or literature and provides bibliographic (which means it makes bibliographies) for universities and higher education establishments. It helps undergraduates and postgraduates. People studying for PhDs or in postdoctoral (postdoc) positions. The service is similar in scope to EndNote or RefWorks or any other reference manager like BibTeX, but it is a social bookmarking service for scientists and humanities researchers.