Quantitative performance of advanced resolution recovery strategies on SPECT images: evaluation with use of digital phantom models

by: Hideo Onishi, Nobutoku Motomura, Koichi Fujino, Takahiro Natsume, Yasuhiro Haramoto
Radiological Physics and Technology In Radiological Physics and Technology, Vol. 6, No. 1. (13 July 2013), pp. 42-53, doi:10.1007/s12194-012-0168-z  Key: citeulike:10907233

Formatted Citation


Show HTML

Likes (beta)

This copy of the article hasn't been liked by anyone yet.

View FullText article


Abstract

Several resolution recovery (RR) methods have been developed. This study was aimed to validate the following performance of the advanced RR methods: Evolution™, Astonish™, Flash3D™, and 3D-OSEM. We compared the advanced RR method with filtered back projection (FBP) and standard order-subset expectation maximization (OSEM) using resolution (RES), cylinder/sphere (CYS), and myocardial (MYD) digital phantoms. The RES phantom was placed in three spheres. Sixteen spheres (hot and cold) were then placed in a concentric configuration (diameter: 96–9.6 mm) inside the CYS phantom. The MYD phantom was created by computer simulation with the use of an electron γ-shower 4 (EGS4) and it included two left ventricular defects in the myocardium. The performance was evaluated at source-to-detector distances ( R -distance) of 166, 200, and 250 mm with reconstruction parameters (product of subset and iteration: SI) with use of the resolution recovery factor, count recovery, normalized mean square error (NMSE), and %CV. According to increased SI updates, the value of the FWHM decreased, and the effect was more obvious as the R -distance increased. The spatial resolution of the advanced RR method was 20 % better than that of FBP and OSEM. The resolution recovery ratio was 80 %, and the count recovery was maintained only in objects with a diameter of >30 mm in the advanced RR method. The NMSE and %CV was 50 and 30 % improved over FBP and OSEM, respectively. The advanced RR method caused overestimation due to Gibbs’s phenomenon in the marginal region when the diameter of the sphere was 16–28.8 mm.


Olmi's tags for this article

Citations (CiTO)

No CiTO relationships defined

X There are no reviews yet

X Find related articles with these CiteULike tags

X Posting History


X Export records

Privacy Statement | Terms & Conditions
CiteULike organises scholarly (or academic) papers or literature and provides bibliographic (which means it makes bibliographies) for universities and higher education establishments. It helps undergraduates and postgraduates. People studying for PhDs or in postdoctoral (postdoc) positions. The service is similar in scope to EndNote or RefWorks or any other reference manager like BibTeX, but it is a social bookmarking service for scientists and humanities researchers.