Comparison of Methods to Measure Low Serum Estradiol Levels in Postmenopausal Women Export

J Clin Endocrinol Metab, Vol. 91, No. 10. (1 October 2006), pp. 3791-3797.

Citation Format

[Posts]

View FullText article


Zephyrus's tags for this article

comparison estradiol estrogen low-level measurement new-assay postmenopausal

X Reviews [Write a review of this article]

X Find related articles from these CiteULike users

X Find related articles with these CiteULike tags

X Posting History

X Abstract

Context: Accurate measurement of low serum estradiol (E2 < 30 pg/ml or < 110 pmol/liter) is needed to study relationships between endogenous E2 and risks of diseases in older women. Objective: The objective of this study was to determine whether an extraction-based (indirect) assay or a non-extraction-based (direct) assay correlates better with mass spectrometry and body mass index (BMI). Design/Setting: In a pilot study of 40 postmenopausal women, endogenous E2 measurements from three indirect and four direct assay methods and gas chromatography-tandem mass spectrometry (GC-MS/MS) were compared. A confirmatory study compared an indirect and a direct assay, selected among those in the pilot study, to GC-MS/MS; this study was conducted in 374 postmenopausal women not taking hormone therapy from the Ultra Low-dose TRansdermal estrogen Assessment (ULTRA) trial. Main Outcomes: Pearson correlation coefficients among E2 measurements by assay methods and BMI, and their confidence intervals, by bias-corrected bootstrap method, were used. Results: In the pilot study, E2 by three indirect assays correlated better (P < 0.03) with GC-MS/MS and with BMI than measurements by four direct assays. In the confirmatory study, the indirect assay correlated better (P < 0.01) with GC-MS/MS and BMI than the direct assay. Measurements by the indirect and direct assays were overestimated, but deviations in direct assay measurements were less precise. Mean E2 by the indirect and direct assays were higher (by 14 and 68%, respectively) and less reproducible than by GC-MS/MS. Conclusion: Until mass spectrometry is practical for wide use, extraction-based indirect assays may be preferable for measuring low postmenopausal serum E2. 10.1210/jc.2005-2378


X BibTeX record

X RIS record


Privacy Statement | Terms & Conditions
CiteULike organises scholarly (or academic) papers or literature and provides bibliographic (which means it makes bibliographies) for universities and higher education establishments. It helps undergraduates and postgraduates. People studying for PhDs or in postdoctoral (postdoc) positions. The service is similar in scope to EndNote or RefWorks or any other reference manager like BibTeX, but it is a social bookmarking service for scientists and humanities researchers.