X-ray backlighting for the National Ignition Facility (invited)by: O. L. Landen, D. R. Farley, S. G. Glendinning, L. M. Logory, P. M. Bell, J. A. Koch, F. D. Lee, D. K. Bradley, D. H. Kalantar, C. A. Back, R. E. Turner
Papers from the thirteenth topical conference on high temperature plasma diagnostics, Vol. 72, No. 1. (2001), pp. 627-634.
|
Reviews
[Write a review of this article]
Find related articles from these CiteULike users
Find related articles with these CiteULike tags
Posting History
AbstractX-ray backlighting is a powerful tool for diagnosing a large variety of high-density phenomena. Traditional area backlighting techniques used at Nova and Omega cannot be extended efficiently to National Ignition Facility scale. New, more efficient backlighting sources and techniques are required and have begun to show promising results. These include a backlit-pinhole point-projection technique, pinhole and slit arrays, distributed polychromatic sources, and picket-fence backlighters. In parallel, there have been developments in improving the data signal-to-noise and, hence, quality by switching from film to charge-coupled-device-based recording media and by removing the fixed-pattern noise of microchannel-plate-based cameras. ©2001 American Institute of Physics.