Motion Correction of Multi-b-value Diffusion-weighted Imaging in the Liver

by: Yousef Mazaheri, Richard K. G. Do, Amita Shukla-Dave, Joseph O. Deasy, Yonggang Lu, Ogus Akin
Academic Radiology (September 2012), doi:10.1016/j.acra.2012.07.005  Key: citeulike:11201781

Formatted Citation


Show HTML

Likes (beta)

This copy of the article hasn't been liked by anyone yet.

View FullText article


Abstract

Motion artifacts are a significant source of error in the acquisition and quantification of parameters from multi-b-value diffusion-weighted imaging (DWI). The objective of this article is to present a reliable method to reduce motion-related artifacts during free-breathing at higher b-values when signal levels are low. Twelve patients referred for magnetic resonance imaging of the liver underwent a clinical magnetic resonance imaging examination of the abdominal region that included DWI. Conventional single-shot spin-echo echo planar imaging acquisitions of the liver during free breathing were repeated in a “time-resolved” manner during a single acquisition to obtain data for multi-b-value analysis, alternating between low and high b-values. Image registration using a normalized mutual information similarity measure was used to correct for spatial misalignment of diffusion-weighted volumes caused by motion. Registration error was estimated indirectly by comparing the normalized root-mean-square error (NRMSE) values of data fitted to the biexponential intra-voxel incoherent motion model before and after motion correction. Regions of interest (ROIs) were selected in the liver close to the surface of the liver and close to internal structures such as large bile ducts and blood vessels. For the 12 patient datasets, the mean NRMSE value for the motion-corrected ROIs (0.38 ± 0.16) was significantly lower than the mean NRMSE values for the non–motion-corrected ROIs (0.41 ± 0.13) (P < .05). In cases where there was substantial respiratory motion during the acquisition, visual inspection verified that the algorithm markedly improved alignment of the liver contours between frames. The proposed method addresses motion-related artifacts to increase robustness in multi-b-value acquisitions.


anitabanerji's tags for this article

Citations (CiTO)

No CiTO relationships defined

X There are no reviews yet

X Find related articles with these CiteULike tags

X Posting History


X Export records

Privacy Statement | Terms & Conditions
CiteULike organises scholarly (or academic) papers or literature and provides bibliographic (which means it makes bibliographies) for universities and higher education establishments. It helps undergraduates and postgraduates. People studying for PhDs or in postdoctoral (postdoc) positions. The service is similar in scope to EndNote or RefWorks or any other reference manager like BibTeX, but it is a social bookmarking service for scientists and humanities researchers.