Modified Langley plot method for measuring the spectral aerosol optical thickness and its daily variations Export

Appl. Opt., Vol. 31, No. 12. (20 April 1992), pp. 2154-2162.

Citation Format

[Posts]

View FullText article


harish's tags for this article

aod instrument sun-photometer

X Reviews [Write a review of this article]

X Find related articles from these CiteULike users

X Find related articles with these CiteULike tags

X Posting History

X Abstract

A method of obtaining the spectral aerosol optical thickness that uses a multispectral instrument and a crude instrument with one spectral band only, here the blue at 450 nm, is presented. The instrument in the blue range is calibrated from a stratospheric balloon. The method is shown to be efficient by using experimental data collected in West Africa, where the daily variations of the aerosol optical thicknesses are large because of frequent dust storms and where the classic Langley plot method could not be used.


X BibTeX record

X RIS record


Privacy Statement | Terms & Conditions
CiteULike organises scholarly (or academic) papers or literature and provides bibliographic (which means it makes bibliographies) for universities and higher education establishments. It helps undergraduates and postgraduates. People studying for PhDs or in postdoctoral (postdoc) positions. The service is similar in scope to EndNote or RefWorks or any other reference manager like BibTeX, but it is a social bookmarking service for scientists and humanities researchers.