CiteULike is a free online bibliography manager. Register and you can start organising your references online.

Physiological noise reduction for arterial spin labeling functional MRI. Export

Neuroimage (10 March 2006)

Citation Format

[Posts]

View FullText article


jcohenadad's tags for this article

asl fmri glm physiological-noise

X Reviews [Write a review of this article]

X Notes for this article

jcohenadad has 0 private notes and 1 public note for this article.

application of RETROICOR method on ASL data

jcohenadad (public note) - 2006-09-21 19:09:32

X Find related articles from these CiteULike users

X Find related articles with these CiteULike tags

X Posting History

X Abstract

Three methods for the reduction of physiological noise in arterial spin labeling (ASL) functional magnetic resonance imaging (fMRI) are presented and compared. The methods are based upon a general linear model of the ASL measurement process and on a previously described retrospective image-based method (RETROICOR) for physiological noise reduction in blood oxygenation level dependent fMRI. In the first method, the contribution of physiological noise to the interleaved control and tag images that comprise the ASL time series are assumed to be equal, while in the second method this assumption is not made. For the third method, it is assumed that physiological noise primarily impacts the perfusion time series obtained from the filtered subtraction of the control and tag images. The methods were evaluated using studies of functional activity in the visual cortex and the hippocampal region. The first and second methods significantly improved statistical performance in both brain regions, whereas the third method did not provide a significant gain. The second method provided significantly better performance than the first method in the hippocampal region, whereas the differences between methods were less pronounced in visual cortex. The improved performance of the second method in the hippocampal region appears to reflect the relatively greater effect of cardiac fluctuations in this brain region. The proposed methods should be particularly useful for ASL studies of cognitive processes where the intrinsic signal to noise ratio is typically lower than for studies of primary sensory regions.


X BibTeX record

X RIS record


Privacy Statement | Terms & Conditions
CiteULike organises scholarly (or academic) papers or literature and provides bibliographic (which means it makes bibliographies) for universities and higher education establishments. It helps undergraduates and postgraduates. People studying for PhDs or in postdoctoral (postdoc) positions. The service is similar in scope to EndNote or RefWorks or any other reference manager like BibTeX, but it is a social bookmarking service for scientists and humanities researchers.