Decision and Control, 2001. Proceedings of the 40th IEEE Conference on In Decision and Control, 2001. Proceedings of the 40th IEEE Conference on, Vol. 2 (2001), pp. 1168-1173 vol.2, doi:10.1109/.2001.981043 Key: citeulike:1133613
Formatted Citation
Show HTML
Likes
(beta)
This copy of the article hasn't been liked by anyone yet.
In this paper an experimental comparison is made between six different techniques to control the position of a pneumatic actuator. Six different reference signals have been tested on each control technique. The methods considered are: (A) PID, (B) fuzzy, (C) PID with pressure feedback, (D) fuzzy with pressure feedback, (E) sliding mode and (F) neuro-fuzzy control. In the last method, proposed by the authors, the differential pressure sensor has been replaced by a neural network based estimator. Details of each control method and the results obtained are given and finally a global comparison is made with several critical considerations