Ultrasound measurements on acromio-humeral distance and supraspinatus tendon thickness: test-retest reliability and correlations with shoulder rotational strengths.

by: Hio-Teng T. Leong, Sammi Tsui, Michael Ying, Vivian Yee-Fong Y. Leung, Siu N. Fu
Journal of science and medicine in sport / Sports Medicine Australia, Vol. 15, No. 4. (July 2012), pp. 284-291, doi:10.1016/j.jsams.2011.11.259  Key: citeulike:11560557

Formatted Citation


Show HTML

Likes (beta)

This copy of the article hasn't been liked by anyone yet.

View FullText article


Abstract

To establish the test-retest reliability of ultrasound measurements on acromio-humeral distance (AHD) and supraspinatus tendon thickness; and to explore their relationships with shoulder rotational strengths. Test-retest observational study. Thirty-seven individuals (age: 21.5±1.4 years) participated in this study. Twenty-four were University volleyball players with 15 healthy and 9 players with shoulder impingement syndrome (SIS). Thirteen participants were healthy untrained individuals. Ultrasound measurements of AHD and supraspinatus tendon thickness were taken, and isokinetic testing of concentric shoulder internal rotation (IR) and external rotation (ER) at a speed of 90°/s was performed. The measurement of the AHD and the supraspinatus tendon thickness indicated excellent reliability (ICC=0.922, and ICC=0.933 respectively), and the minimum detectable difference (MDD) were 2.10mm and 0.64 mm respectively. A cut-off AHD distance of 23.9 mm had a sensitivity of 0.67 and specificity of 0.71 (area under curve (AUC): 0.70; p=0.05) in identifying individuals with and without SIS. Hence, individuals with AHD larger than 23.9 mm had greater possibility of having SIS. Positive correlations were found in AHD with supraspinatus tendon thickness (r=0.36, p<0.05) and shoulder external rotational strengths (r=0.47-0.62, all p<0.05) and ER/IR ratios (r=0.56-0.58, all p<0.05). Ultrasound measurements of AHD and tendon thickness have excellent reliability. The reported cut-off AHD highlighted the potential role of ultrasound measurements in volleyball players for early identification of SIS. The AHD was related to the supraspinatus tendon thickness and shoulder external rotation strengths. Our findings provide a scientific basis for muscle training in overhead athletes such as volleyball players. Copyright © 2011 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.


naoking's tags for this article

Citations (CiTO)

No CiTO relationships defined

X There are no reviews yet

X Posting History


X Export records

Privacy Statement | Terms & Conditions
CiteULike organises scholarly (or academic) papers or literature and provides bibliographic (which means it makes bibliographies) for universities and higher education establishments. It helps undergraduates and postgraduates. People studying for PhDs or in postdoctoral (postdoc) positions. The service is similar in scope to EndNote or RefWorks or any other reference manager like BibTeX, but it is a social bookmarking service for scientists and humanities researchers.