CiteULike is a free online bibliography manager. Register and you can start organising your references online.

The relationship between the intracranial pressure–volume index and cerebral autoregulation Export

Intensive Care Medicine, Vol. 35, No. 3. (1 March 2009), pp. 546-549.

Citation Format

[Posts]

View FullText article


X Reviews [Write a review of this article]

X Find related articles from these CiteULike users

X Find related articles with these CiteULike tags

X Posting History

X Abstract

Abstract Objective  The pressure–volume index (PVI) can be used to assess the cerebrospinal fluid dynamics and intracranial elastance in critically ill brain injured patients. The dependency of PVI on the state of cerebral autoregulation within the physiologic range of cerebral perfusion pressure (CPP) can be described by mathematical models that account for changes in cerebral blood volume during PVI testing. This relationship has never been verified clinically using direct PVI measurement and independent cerebral autoregulation assessment. Design, setting, and patients  PVI and cerebral autoregulation were prospectively assessed in a cohort of 19 comatose patients admitted to an academic intensive care unit in Brescia, Italy. Intervention  None. Methods  PVI was measured injecting a fixed volume of 2 ml of 0.9% sodium chloride solution into the cerebral ventricles through an intraventricular catheter. Cerebral autoregulation was assessed using transcranial Doppler transient hyperaemic response (THR) test. Measurements and results  Fifty-nine PVI assessments and 59 THR tests were performed. Mean PVI was 20.0 (SD 10.2) millilitres in sessions when autoregulation was intact (THR test ≥1.1) and 31.6 (8.8) millilitres in sessions with defective autoregulation (THR test <1.1) (ΔPVI = 11.7 ml, 95% CI = 4.7–19.3 ml; P = 0.002). Intracranial pressure, CPP and brain CT findings were not significantly different between the measurements with intact and disturbed autoregulation. Conclusions  Cerebral autoregulation status can affect PVI estimation despite a normal CPP. PVI measurement may overestimate the tolerance of the intracranial system to volume loads in patients with disturbed cerebral autoregulation.


X BibTeX record

X RIS record


Privacy Statement | Terms & Conditions
CiteULike organises scholarly (or academic) papers or literature and provides bibliographic (which means it makes bibliographies) for universities and higher education establishments. It helps undergraduates and postgraduates. People studying for PhDs or in postdoctoral (postdoc) positions. The service is similar in scope to EndNote or RefWorks or any other reference manager like BibTeX, but it is a social bookmarking service for scientists and humanities researchers.