Insulin sensitivity (Si) assessment in lean and overweight subjects using two different protocols and updated software.

by: Anwar Borai, Callum Livingstone, Shahida Shafi, Hawzen Zarif, Gordon Ferns
Scandinavian journal of clinical and laboratory investigation, Vol. 70, No. 2. (April 2010), pp. 98-103, doi:10.3109/00365510903544585  Key: citeulike:12069203

Formatted Citation


Show HTML

Likes (beta)

This copy of the article hasn't been liked by anyone yet.

View FullText article


Abstract

The standard frequently-sampled intravenous glucose tolerance test (FSIVGTT) is an alternative procedure to the clamp technique for estimating the insulin sensitivity (Si) parameter. The goal of this study was to compare Si in lean and overweight individuals in addition to assessing intra-individual reproducibility using two different protocols and updated software. FSIVGTT was carried out in 14 lean (BMI <or= 25 kg/m(2)) and 14 overweight (BMI>25 kg/m(2)) subjects using two different protocols; full (29 samples) and short (12 samples). For reproducibility assessment four normal subjects (triplicate on three and twice on one) were recruited to undergo the same procedure at 1-week intervals. Data analysis was performed using COMAL and Minmod Millennium software. Mean Si (10(-4)min(-1)[pmol/l](-1)) values were significantly different between lean and overweight subjects (p < 0.001) but not between the two protocols using both software packages. For the full and short protocols, Si values were more closely related in lean versus overweight subjects using either COMAL (r = 0.98, p < 0.001), (r = 0.89, p < 0.001) or Minmod Millennium (r = 0.99, p < 0.001), (r = 0.85, p < 0.001) software respectively. The intra-individual reproducibility (%CV) of Si (COMAL) in full versus short protocol was 18.3 +/- 11.1% and 13.7 +/- 1.9% respectively. Reproducibility values for Si (Minmod Millenium) in full versus short protocols were 14.3 +/- 3.8 and 14.9 +/- 1.9% respectively. Si can be assessed accurately by a short protocol FSIVGTT in normal individuals. The short protocol may give less acceptable results for insulin sensitivity in individuals who have normal glucose tolerance but high BMI.


ryszard's tags for this article

Citations (CiTO)

No CiTO relationships defined

X There are no reviews yet

X Posting History


X Export records

Privacy Statement | Terms & Conditions
CiteULike organises scholarly (or academic) papers or literature and provides bibliographic (which means it makes bibliographies) for universities and higher education establishments. It helps undergraduates and postgraduates. People studying for PhDs or in postdoctoral (postdoc) positions. The service is similar in scope to EndNote or RefWorks or any other reference manager like BibTeX, but it is a social bookmarking service for scientists and humanities researchers.