CiteULike is a free online bibliography manager. Register and you can start organising your references online.

In Vivo Validation of a Realistic Kinematic Model for the Trapezio-Metacarpal Joint Using an Optoelectronic System Export

Annals of Biomedical Engineering, Vol. 36, No. 7. (29 July 2008), pp. 1268-1280.

Citation Format

[Posts]

View FullText article


tfx's tags for this article

cor daumen tracking

X Reviews [Write a review of this article]

X Find related articles from these CiteULike users

X Find related articles with these CiteULike tags

X Posting History

X Abstract

Abstract  This article analyzes a realistic kinematic model of the trapezio-metacarpal (TM) joint in the human thumb that involves two non-orthogonal and non-intersecting rotation axes. The estimation of the model parameters, i.e. the position and orientation of the two axes with respect to an anatomical coordinate system, was carried out by processing the motion of nine retroreflective markers, externally attached to the hand surface, surveyed by a video motion capture system. In order to compute the model parameters, prototypical circumduction movements were processed within an evolutionary optimization approach. Quality and reproducibility in assessing the parameters were demonstrated across multiple testing sessions on 10 healthy subjects (both left and right thumbs), involving the complete removal of all markers and then retesting. Maximum errors of less than 5 mm in the axis position and less than 6° in the orientation were found, respectively. The inter-subject mean distance between the two axes was 4.16 and 4.71 mm for right and left TM joints, respectively. The inter-subject mean relative orientation between the two axes was about 106 and 113° for right and left TM joints, respectively. Generalization properties of the model were evaluated quantitatively on opposition movements in terms of distance between measured and predicted marker positions (maximum error less than 5 mm). The performance of the proposed model compared favorably with the one (maximum error in the range of 7–8 mm) obtained by applying a universal joint model (orthogonal and intersecting axes). The ability of in vivo estimating the parameters of the proposed kinematic model represents a significant improvement for the biomechanical analysis of the hand motion.


X BibTeX record

X RIS record


Privacy Statement | Terms & Conditions
CiteULike organises scholarly (or academic) papers or literature and provides bibliographic (which means it makes bibliographies) for universities and higher education establishments. It helps undergraduates and postgraduates. People studying for PhDs or in postdoctoral (postdoc) positions. The service is similar in scope to EndNote or RefWorks or any other reference manager like BibTeX, but it is a social bookmarking service for scientists and humanities researchers.